Tel:0731-8506 0791
E-mail:samy@samycs.com
Add:Tongzipo Road ,Times City, Yuelu District ,Changsha,China
Technical specification |
|
Model |
HAMiLab-V6000 |
Voltage |
AC 380 plus/minus 10V/50Hz, |
Rating power |
9KW |
Microwave output power |
0.5-5.85KW continuously variable |
Microwave frequency |
2.45GHzplus/minus 25MHz |
Max working temperature |
1600 Celsius degree |
Temperature measuring way |
IR thermometer (U.S.A. Raytek), |
Range of temperature measuring |
450 Celsius degree -2250 Celsius degree. |
Temperature accuracy |
plus/minus 0.5% |
Static vacuum degree |
less than100Pa |
Atmosphere system |
air, oxygen, nitrogen, argon, weakly reducing atmospheres, etc |
Max loading space |
Ø150*160mm |
Cycle cooling water flow |
more than 1.5m3/h |
Cycle cooling water pressure |
more than 0.15MPa |
Cycle cooling water total hardness |
less than 60mg/L(tap water can replace it) |
Control system |
embedded system and touch screen, connected with PC, with data
|
Microwave leakage |
less than 1mw/cm2, (national standard is less than 5 mw/cm2) |
System outside dimension |
2200*800*1800mm(L*W*H) |